GW1000-MODTCP

$1,250.00 USD List

Datalink MOD TCP to DH+ |
The DataLink GW1000-MODTCP is a gateway between both Ethernet/IP and AB Ethernet to AB’s DH+ Network.

The GW1000 interfaces any newer AB Ethernet/IP & AB Ethernet PLCs (ie. SLC 5/05, Compactlogix, Micrologix or PLC-5E) or MMI/SCADA/Programming package to any device/node on AB’s DH+. This gateway is a cost-effective alternative to the AB Controllogix Gateway (1756-ENBT and 1756-RIO).

Applications include:
* SCADA/MMI/Programming Software (RLSINX/LOGIX/VIEW,Wondware, Kepware, Citect, Intellution, et. all) packages using AB Ethernet Drivers can read/write data from/to multiple DH+ nodes.

* Any AB Ethernet & Ethernet/IP PLC (MicroLogix, SLC 5/05, CompactLogix, FlexLogix, PLC-5E, ControlLogix) as Master will be able to send either read or write MSG (message) instructions to any DH+ PLC (SLC 5/04, PLC-5).

* DH+ as Master allows applications such as Panelview on DH+ to message SLC 5/05 on Ethernet.
For details, pricing, or to find out if this solution is suitable for your application, please contact us.

Flexibility:
The GW1000 allow multiple Ethernet/IP and AB Ethernet Application to message Multiple DH+ Nodes.

Compact and Lightweight:
Palm-sized, portable freestanding Din Rin/Desktop Controller with USB, AC/DC power option.

Easy Configuration:
All setup is done via Web screen or Telnet.

Cost efficient:
Replace Controllogix (1756-DHRIO/1756-ENBT) functionality and reduces the need to upgrade Legacy DH+ PLCs to newer AB Ethernet Processors.

Specifications:
Physical Dimensions
Size: 0.90″ H x 4.65″ D x 3.98″ W (22.8mm x 118.3mm x 101.0mm)
Weight: 0.66lbs (0.3kg)
Power: 9-27 VDC; Less than 2 WattsInstallation
Plastic enclosure; Freestanding or DIN rail mounting with integrated clipEnvironment
Operating: +32 F to 122 F (0C to +50 C)
Storage: -40 F to +185 F (-40C to +85C)
Humidity: 5% to 95% non-condensing

Protocols

A-B Channel: Allen-Bradley Data Highway Plus or Remote I/O
Ethernet Channel: TCP/IP – 100-Base-T
Serial Channel: DF1 Communications
A-B Channel: Synchronous, DH+/RIO at 57.6, 115.2, and 230.4 Kbaud Ethernet Channel: 100-Base–T; TCP/IP

Serial channel:

Configuration
Integrated web server for configuring communications parameters.Indicators
Power
DH+ status
Serial Status
Serial RX
Serial TX
Ethernet Activity
Ethernet Link Pushbuttons
Reset
ConfigurationHardware
Connections – Top
– 3-pin power – 3.81mm pitch removable screw terminal plug
– 3-pin A-B DH+/RIO – 5.08mm pitch removable screw terminal plug
– RJ45- Ethernet

Connections – Bottom
– 5-pin RS485/RS422 – 3.81mm pitch removable screw terminal plug
– D9 – RS232 port
– USB